PCB News - In the smt factory, the control points and methods of temperature and humidity sensitive components

PCB News

PCB News - In the smt factory, the control points and methods of temperature and humidity sensitive components

In the smt factory, the control points and methods of temperature and humidity sensitive components

2021-10-03
View:474
Author:Frank

In the smt factory, the control points and methods of temperature and humidity sensitive components
Over the years, we are proud to maintain a 99% on-time delivery rate. We work in three shifts to ensure that your PCB can appear on your desk as planned and as early as possible. You can choose DHL and other courier services to balance speed and budget. We only use services from reliable and reputable companies.
24 hours customer service
Whenever you encounter any problems, you can contact the on-site customer service staff to reply to your emails or messages. From the moment you submit the Gerber file to the moment you receive the PCB and assembled PCB, our service staff will follow up your order with satisfaction.


In order to ensure the correct use of temperature and humidity sensitive components in the smt processing of the smt factory, and prevent smt chip components from being affected by moisture, humidity and influence in the environment and using anti-static packaging materials, the following points can be effectively managed and controlled to avoid materials Quality is affected due to improper control.

(1) Environmental control.

pcb board

The temperature and humidity sensitive components are used in the workshop. The ambient temperature is between 18~28 degree Celsius, and the relative humidity is between 40%~60%; when stored, the relative humidity of the moisture-proof box is less than 10%, and the temperature is between 18~28 degree Celsius; the material staff every 4 hours Check the temperature and humidity of the moisture-proof box once, and register its temperature and humidity value in the ``Temperature and Humidity Control Table''; if the temperature and humidity exceed the specified range, immediately notify the relevant personnel to improve, and take corresponding remedial measures (such as placing desiccant, adjusting Room temperature or remove the components from the faulty moisture-proof box and put them into a qualified moisture-proof box). The open time or door open time of the temperature and humidity environment of each enclosed area should not exceed 5 minutes to ensure that the temperature and humidity conditions can continue to be within the control range.

(2) Process control.

a. When unpacking the vacuum packaging of humidity sensitive components on the Smt patch production line, you must wear an electrostatic wristband and electrostatic gloves, and open the vacuum package on a table with good electrostatic protection. After disassembling, check whether the humidity card changes meet the requirements (according to the label requirements on the packaging bag). For smt chip ICs that meet the requirements, add the "Humidity Sensitive Component Control Label" on the packaging.

b. When the production line receives bulk humidity sensitive components, it shall confirm whether the components are qualified according to the "Humidity Sensitive Components Control Label", and give priority to the qualified components.

c. After the humidity sensitive component (IC) is unpacked in the vacuum, the exposure time in the air before reflow shall not exceed the level and life of the humidity sensitive component.

d. For ICs that need to be baked and unqualified, they are handed over to the quality control staff for rejection and returned to the warehouse.

(3) Control method

a. Feeding inspection---the moisture-proof bag should be accompanied by a desiccant bag and a relative humidity card, and relevant text warning slogans should be affixed to the outside of the moisture-proof bag. If the packaging is not good, it needs to be confirmed by the relevant personnel.

b. Material storage-Unopened materials should be stored in accordance with the instructions; unopened materials need to be returned for storage, after baking, put them in a moisture-proof bag and vacuum-sealed; if the unopened materials are not to be used immediately, they should be stored in a low-temperature oven temporarily.

c. On-line operation-unpack it when using it, and check and fill in the humidity indicator card at the same time; fill in the refueling control card and indicate the symbol of the temperature and humidity sensitive component when refueling; the returned materials are packaged according to the corresponding requirements after dehumidification according to the storage regulations. Store.

d. Dehumidification operation-select the baking conditions and time according to the humidity level of smt components, environmental conditions, and unpacking time.

The above is the editor to provide you with the key points and methods for the control of temperature and humidity sensitive components in the smt factory. I hope you can help!
Our factory is located in China. For decades, Shenzhen has been known as the world's electronics R&D and manufacturing center. Our PCB factory and website are approved by the Chinese government, so you can skip the middlemen and buy products on our website with confidence. Because we are a direct factory, this is the reason why 100% of our old customers continue to purchase on iPCB.