Electromagnetic Compatibility and the associated Electromagnetic Interference have historically required system design engineers to keep their eyes peeled, especially in today's world of shrinking PCB board designs and component packaging and OEMs demanding higher-speed systems A headache for PCB layout and design engineers. EMC is closely related to the generation, propagation, and reception of electromagnetic energy, and EMC is not expected in PCB board design. Electromagnetic energy comes from multiple sources mixed together, so special care must be taken to ensure that when different circuits, traces, vias, and PCB board materials work together, the various signals are compatible and do not interfere with each other. EMI, on the other hand, is a destructive effect produced by EMC or unwanted electromagnetic energy. In this electromagnetic environment, PCB board designers must ensure that the generation of electromagnetic energy is reduced so that interference is minimal.
Here are 7 tips to avoid electromagnetic problems in PCB board design:
Tip 1: Ground the PCB
An important way to reduce EMI is to design the ground plane of the PCB board. The first step is to make the ground area as large as possible within the total area of the PCB board, which can reduce emissions, crosstalk and noise. Special care must be taken when connecting each component to a ground point or plane, otherwise, the neutralizing effect of a reliable ground plane cannot be fully utilized. A particularly complex PCB board design has several stable voltages. Ideally, each reference voltage has its own corresponding ground plane. However, if there are too many ground planes, it will increase the manufacturing cost of the PCB board and make the price too high. The compromise is to use ground planes in three to five different locations, each of which can contain multiple ground sections. This not only controls the manufacturing cost of the circuit board but also reduces EMI and EMC. A low impedance grounding system is important if you want to keep the EMC small. In a multi-layer PCB, it is good to have a solid ground plane rather than a copper balance block or scattered ground plane because it has low impedance, provides a current path, and is a good source of reverse signals. To solve EMC problems in multilayer PCBs, it is good to have a solid ground plane instead of copper thieving or scattered ground planes. The length of time the signal takes to return to the ground is also very important. The time for the signal to and from the source must be comparable, otherwise, an antenna-like phenomenon occurs where the radiated energy becomes part of the EMI. Also, traces that carry current to/from the signal source should be as short as possible, if the source and return paths are not of equal length, there will be a ground bounce, which will also generate EMI. If the timing of the signal entering and leaving the source is not synchronized, an antenna-like phenomenon occurs, radiating energy and causing EMI.
Tip 2: Differentiate EMI
Since EMI is different, a good EMC design rule is to separate analog and digital circuits. Analog circuits with higher amperage or current should be kept away from high-speed traces or switching signals. If possible, they should be protected with a grounded signal. On a multi-layer PCB, analog traces should be routed on one ground plane, while switch or high-speed traces should be on the other. Therefore, signals of different characteristics are separated. A low-pass filter can sometimes be used to remove high-frequency noise coupled with surrounding traces. The filter suppresses noise and returns a stable current. It is important to separate the ground planes for analog and digital signals. Since analog and digital circuits have their own unique characteristics, it is important to separate them. Digital signals should have a digital ground, and analog signals should terminate at the analog ground. In digital circuit design, experienced PCB board layout and design engineers pay special attention to high-speed signals and clocks. At high speeds, the signals and clocks should be as short as possible and adjacent to the ground plane because, as mentioned earlier, the ground plane keeps crosstalk, noise, and radiation under control. Digital signals should also be kept away from power planes. If the distance is close, noise or induction can be created, which can weaken the signal.
Tip 3: Crosstalk and traces are the focus
Traces are especially important to ensure proper current flow. If the current is coming from an oscillator or other similar device, it is especially important to keep the current separated from the ground plane, or not to run the current in parallel with another trace. Two parallel high-speed signals generate EMC and EMI, especially crosstalk. The resistance path must be kept short and the return current path as short as possible. The return path trace should be the same length as the transmit trace. For EMI, one is called the "aggressor trace" and the other is the "victim trace". Inductive and capacitive coupling can affect "victim" traces due to the presence of electromagnetic fields, causing forward and reverse currents on the "victim traces". In this case, ripples are generated in a stable environment where the transmit and receive lengths of the signal is almost equal. In a well-balanced environment with stable traces, the induced currents should cancel each other out to eliminate crosstalk. However, we live in an imperfect world where such a thing does not happen. Therefore, our goal must be to keep the crosstalk of all traces to a very small level. If the width between parallel traces is twice the trace width, the effect of crosstalk can be minimized. For example, if the trace width is 5 mils, the small distance between two parallel traces should be 10 mils or more. As new materials and new components continue to emerge, PCB board designers must also continue to deal with electromagnetic compatibility and interference issues.
Tip 4: Decoupling Capacitors
Decoupling capacitors reduce the unwanted effects of crosstalk and should be placed between the power and ground pins of the device to ensure low AC impedance, reducing noise and crosstalk. To achieve low impedance over a wide frequency range, multiple decoupling capacitors should be used. Using decoupling capacitors around the ball grid array reduces crosstalk. An important rule of thumb for placing decoupling capacitors is to place small value capacitors as close to the device as possible to reduce inductive effects on traces. This particular capacitor is placed as close as possible to the device's power pins or power traces and connects the capacitor's pads directly to vias or ground planes. If the traces are long, use multiple vias so that the ground impedance is low.
Tip 5: Avoid 90-degree angles
To reduce EMI, avoid traces, vias, and other components that form a 90° angle, as right angles will generate radiation. At this corner, the capacitance will increase and the characteristic impedance will change, causing reflections, which in turn cause EMI. To avoid 90° corners, traces should be routed to the corners with at least two 45° corners.
Tip 6: Use vias with caution
In almost all PCB board layouts, vias must be used to provide conductive connections between different layers. PCB layout engineers need to be especially careful because vias create inductance and capacitance. In some cases, they also produce reflections because the characteristic impedance changes when vias are made in the trace. Also, keep in mind that vias increase trace length and need to be matched. In the case of differential traces, vias should be avoided as much as possible. If unavoidable, vias should be used in both traces to compensate for delays in the signal and return paths.
Tip 7: Cables and Physical Shielding
Cables carrying digital circuits and analog currents create parasitic capacitance and inductance that cause many EMC-related problems. If a twisted pair cable is used, the coupling level is kept low, eliminating the resulting magnetic field. For high-frequency signals, shielded cables must be used, with both the front and background to eliminate EMI interference. Physical shielding is the encapsulation of the whole or part of the system with a metal package to prevent EMI from entering the circuit on the PCB board. This shield acts like an enclosed grounded conductive container, reducing antenna loop size and absorbing EMI.