Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | degree Celsius | 135 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | degree Celsius | 310 | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/ degree Celsius | 55 | |
After Tg | ppm/ degree Celsius | 308 | |||
50-260 degree Celsius | % | 4.5 | |||
Thermal Stress | IPC-TM-650 2.4.24.13 | 288 degree Celsius, solder dip | -- | >100S No Delamination | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 5.0E + 08 | |
E-24/125 | MΩ.cm | 5.0E + 06 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 5.0E + 07 | |
E-24/125 | MΩ | 5.0E + 06 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 126 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | 60 | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.7 | |
IEC 61189-2-721 | 10GHz | -- | - | ||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.016 | |
IEC 61189-2-721 | 10GHz | -- | - | ||
Peel Strength (1oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | - | |
After thermal Stress 288 degree Celsius,10s | N/mm | 1.8 | |||
125 degree Celsius | N/mm | 1.6 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 550 |
CW | IPC-TM-650 2.4.4 | A | MPa | 450 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105_D-24/23 | % | 0.10 | |
CTI | IEC60112 | A | Rating | PLC 0 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
1. Specification sheet: IPC-4101/21, is for your reference only.
2. All the typical value is based on the 1.6mm specimen,while the Tg is for specimen≥0.50mm.
3. All the typical value listed above is for your reference only,please turn to Shengyi Technology Co., Ltd. for detailed information, and all rights from this data sheet are reserved by Shengyi Technology Co., Ltd.
Explanations: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning
The figures following the letter symbols indicate with the first digit the duration of the preconditioning in hours, with the second digit the preconditioning temperature in degree Celsius and with the third digit the relative humidity.